Introductio Systematis Probationis Generatoris Impulsus Altae Tensionis
Varias generatorum impulsuum probationes ab 100KV ad 1200KV habemus. Inter partes systematis sunt generator impulsuum IVG, systema onerationis DC LGR, divisor capacitivus impedantiae humilis CR, systema moderationis intellegens IGCS, systema mensurae et analysis digitalis IVMS, et instrumentum secandi multi-hiatus MCG.
| Tensio Aestimata (KV) | 100KV-6000KV |
| Energia aestimata (kJ) | 2.5-240KJ |
| Tensio onerandi aestimata | ±100kV ±200kV |
| Capacitas scaenae | 1.0μF/200kV 2.0μF/100kV()secundum capacitatem totalem() |
| Impulsus fulminis ordinarius | Efficacia 1.2/50μS: 85 ~ 90% (1.2±30%/50±20%µS) |
| Impulsus commutationis | Efficacia 250/2500μS: 65 ~ 70% (250±20%/2500±60%µS) |
| Temperatura operationis pro componente HV | +10 ~ +45℃ |
| Humiditas relativa partium electronicarum | 80% |
| Altitudo maxima | Mille metra |
| Humiditas relativa partis HV (non condensans) | 95% |